[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15034056
Date Manufactured	25/04/2013
Lot	WO0000109329779
DesignStudio ID	26574
Target Plexity	76
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
BCL2	NM_000633	6665875	1	0	Homo sapiens	hg19	chr18	60986441	60986151	TTGACAGAGGATCATGCTGTACT	3	CAGAGGAAGTAGACTGATATTAACAATACT	1	MINUS	ILLUMINA	1.37	false	FromReportXYZ;FromStudyXYZ
BMP2	NM_001200	6770547	1	2	Homo sapiens	hg19	chr20	6751083	6758932	AGCCGAGCCAACACTGTGCGCAGCTT	1	TACCAGAAACGAGTGGGAAAACAACC	1	PLUS	ILLUMINA	1.734	false	FromStudyXYZ
BMP4	NM_130851	6717860	3	2	Homo sapiens	hg19	chr14	54418607	54417563	AGCCGGGCCAACACCGTGAGGAGCTT	1	TCCCAGGGACCAGTGAAAACTCTGCTTTT	1	MINUS	ILLUMINA	1.567	false	
BMP5	NM_021073	6778350	6	5	Homo sapiens	hg19	chr6	55623833	55620437	TGCCACCAACCACGCTATAGTTCA	3	CACGTACCAAAGCCTTGTTGTGC	3	MINUS	ILLUMINA	1.385	false	
BMP6	NM_001718	6833559	0	1	Homo sapiens	hg19	chr6	7727822	7845416	GCGGACATGGTCATGAGCTTTGTGAA	3	CTCCCCTCGTCAGCGACACCACAAA	1	PLUS	ILLUMINA	1.723	false	
BMP7	NM_001719	6634273	1	0	Homo sapiens	hg19	chr20	55840789	55803451	CGACATGGTCATGAGCTTCGTCAA	5	GGAACATGACAAGGAATTCTTCCACC	1	MINUS	ILLUMINA	1.732	false	
BMP8B	NM_001720	6845976	6	5	Homo sapiens	hg19	chr1	40228800	40226209	CATGAATGCCACCAACCACGCCAT	6	TGATGATGCCAGACGCAGTCCCCAA	3	MINUS	ILLUMINA	1.551	false	
BOC	NM_033254	6709878	18	19	Homo sapiens	hg19	chr3	113004378	113005558	CCTGGAAGCAGTGTGGGACCCTCCATTT	1	TGGGCCTTGTGCCAGTTGAAGA	8	PLUS	ILLUMINA	1.327	false	
BTRC	NM_033637	6714787	13	14	Homo sapiens	hg19	chr10	103310618	103312954	ATAACCATACACTGACCTCATACTTGCC	1	CGGTATTTAACGTATCTGCCAATACCAG	1	PLUS	ILLUMINA	1.945	false	
CDON	NM_016952	6673362	18	17	Homo sapiens	hg19	chr11	125848233	125831866	TGTGTTAACTGCCGAAATTGTCGAAAC	2	TGTTTCACCAAAACCAACAGCACTTTC	3	MINUS	ILLUMINA	1.995	false	
CSNK1A1	NM_001025105	6653540	10	9	Homo sapiens	hg19	chr5	148885044	148876383	CAAGCAAACTGACAAAACCAAGAGTAAC	4	TTGAGGAACAGAAGAAGCAGAGCAGA	6	MINUS	ILLUMINA	1.935	false	
CSNK1E	NM_152221	6740751	2	1	Homo sapiens	hg19	chr22	38710117	38699216	GGGAGCGGGTCCTTCGGAGATATCTA	2	CTGGTGAGGAAGTCGCCATCAAG	3	MINUS	ILLUMINA	1.489	false	
CTNNB1	NM_001098210	6833702	13	14	Homo sapiens	hg19	chr3	41279531	41280664	GGTGCCCAGGGAGAACCCCTTGGATAT	1	CTTTTCACTCTGGTGGATATGGCCA	3	PLUS	ILLUMINA	1.749	false	
DHH	NM_021044	6674108	1	0	Homo sapiens	hg19	chr12	49488018	49485147	GTGGAGCCGACCGCCTGATGAC	1	TTGTAAGGAGCGGGTGAACGCTTT	2	MINUS	ILLUMINA	1.163	false	
DISP1	NM_032890	6652808	3	4	Homo sapiens	hg19	chr1	223116645	223156447	GCCTGTGCAACAGCACATAGCCAACATAA	1	ACCATCCAGACCTTTCAAGTTGCCAA	2	PLUS	ILLUMINA	1.815	false	
DISP2	NM_033510	6623257	6	7	Homo sapiens	hg19	chr15	40657899	40659280	TTCCATGTGTCGCATGGAACAGGA	3	ATCCGCTCCCATACCAGCTTCG	1	PLUS	ILLUMINA	1.221	false	
ERBB4	NM_005235	6613541	4	3	Homo sapiens	hg19	chr2	212652784	212615404	CTTGACTCTTGTGTCAACAAATGGTAG	1	TGGACGTTGCCATAAGTCCTGTACT	1	MINUS	ILLUMINA	1.881	false	
FAT4	NM_024582	6598269	15	16	Homo sapiens	hg19	chr4	126408735	126411099	ATCAAGCACATCGAGATGCCCAAA	1	TGCTTCTATGTGGTATGGTGGAGAA	1	PLUS	ILLUMINA	1.668	false	
FBXW11	NM_033644	6625020	6	5	Homo sapiens	hg19	chr5	171318501	171305100	TATCAGTGGCCTACGAGATAATTCT	3	ATAAAACCAGCCTGGAATGTTTGAAAG	2	MINUS	ILLUMINA	1.865	false	
FGF9	NM_002010	6790719	1	2	Homo sapiens	hg19	chr13	22255252	22275362	GGGATGAATGAGAAGGGGGAGCTGTAT	1	TAACCCAAGAGTGTGTATTCAGAGAAC	1	PLUS	ILLUMINA	1.956	false	
FGFR3	NM_001163213	6698989	16	17	Homo sapiens	hg19	chr4	1808633	1808879	ACCGTGTCCTTACCGTGACGTC	3	TGTCGGCGCCTTTCGAGCAGTACT	1	PLUS	ILLUMINA	1.155	false	
FKBP8	NM_012181	6644398	5	4	Homo sapiens	hg19	chr19	18649058	18648541	TCGCCATCAAGGCTATCACCTCCA	2	GAGGAGGCACAGCTCCTGCAGTTGAA	1	MINUS	ILLUMINA	1.609	false	
FOXE1	NM_004473	6598612	0	0	Homo sapiens	hg19	chr9	100617233	100617307	TCGGAGGGGCCAGTGCAGGCGCCTACCAT	1	CCCGGTGGGATAGATCGGTTCGTGT	1	PLUS	ILLUMINA	1.324	false	
FRMD6	NM_001042481	6686039	13	14	Homo sapiens	hg19	chr14	52192558	52194506	TCGTGGCCAGAGTACTGATTCTCTT	1	ACCTCCACTGATCGACACAGCTT	4	PLUS	ILLUMINA	1.507	false	
GLI1	NM_005269	6633250	8	9	Homo sapiens	hg19	chr12	57861246	57861819	GAGCCAAGCACCAGAATCGGACCCATT	2	CCTGGCTGCACCAAACGCTATA	6	PLUS	ILLUMINA	1.378	false	
GLI2	NM_005270	6709455	1	2	Homo sapiens	hg19	chr2	121685014	121708859	GAGCCTCATTCTGTCCACGGTGT	3	CGGCAGCCCTGTCATCTCTGACATCT	1	PLUS	ILLUMINA	1.475	false	
GLI3	NM_000168	6785534	4	3	Homo sapiens	hg19	chr7	42116383	42088257	TTACGATCCATCTCCGATTCCTCCAT	1	GTAGCCCTACGTATCCGGACCT	2	MINUS	ILLUMINA	1.426	false	
GSK3B	NM_002093	6801970	5	4	Homo sapiens	hg19	chr3	119634927	119631627	CTGATACTGCTGTATTAAAACTCTGTGAC	1	AGCAGCTGGTCCGAGGAGAACCCAAT	3	MINUS	ILLUMINA	1.743	false	
HHAT	NM_018194	6786133	8	9	Homo sapiens	hg19	chr1	210686504	210761275	GATGTTGGACTGCATAATTTCTTAATCAGG	1	CATTCCAGTGGGCGGGTCCCAGCAT	1	PLUS	ILLUMINA	1.481	false	
HHIP	NM_022475	6860759	1	2	Homo sapiens	hg19	chr4	145573919	145579973	TTCTTTTACACTTGCCGAGGCCAT	5	TCAAACAACTGCGGATGAGTTTTGC	1	PLUS	ILLUMINA	1.67	false	
IFT52	NM_016004	6695277	7	8	Homo sapiens	hg19	chr20	42247632	42249540	AATATTTGGACAAAGAAGAAAACAGCA	1	TGGCTCACGACAGGAGACATCCACCTAAA	1	PLUS	ILLUMINA	1.756	false	
KCTD11	NM_001002914	6773911	0	0	Homo sapiens	hg19	chr17	7256703	7256767	AGGGCAGAGGGGAGCCCACATTTTCAT	1	CCCGCCCCGTGGAACTCCCCGAGGT	1	PLUS	ILLUMINA	1.41	false	
LATS1	NM_004690	6758732	7	6	Homo sapiens	hg19	chr6	149997430	149983335	TCTTGGCACAAACACCATTAGAAACAC	1	AAACATCTCTTCACATTCCACCACAAG	2	MINUS	ILLUMINA	1.997	false	
LATS2	NM_014572	6819358	2	1	Homo sapiens	hg19	chr13	21619849	21565516	AACTGGTGAACGCAGGATGCGA	2	GATGGCTGGCCGAGCTCTCAAGCAGA	1	MINUS	ILLUMINA	1.285	false	
LRP2	NM_004525	6840096	2	1	Homo sapiens	hg19	chr2	170177317	170175362	TGTTCAGATGACGCGGATGAAATTGG	1	CCTGCCAGCAGGGCTATTTCAAGT	5	MINUS	ILLUMINA	1.708	false	
MAPK1	NM_002745	6638935	5	4	Homo sapiens	hg19	chr22	22143017	22142649	GAAGCATTATCTTGACCAGCTGAACC	1	TATTCTTGGATCCCCATCACAAGAAGAC	1	MINUS	ILLUMINA	1.941	false	
MTSS1	NM_014751	6725119	3	2	Homo sapiens	hg19	chr8	125711793	125603447	TGGCTGACATGGCCACCAACACA	8	GGACCAGGGAGATTGGATCTGCTCTCA	1	MINUS	ILLUMINA	1.513	false	
NF2	NM_181832	6761335	13	14	Homo sapiens	hg19	chr22	30074278	30077456	ATGAAGCGGCTTTCCATGGAGATAGA	1	GTGGAATACATGGAAAAGAGCAAGCATC	1	PLUS	ILLUMINA	1.939	false	
NPC1	NM_000271	6627112	9	8	Homo sapiens	hg19	chr18	21134752	21131648	ATTACCACACGCACTTTCTGTACTGC	1	TACAAGTTTGCTCCATGACCCTT	5	MINUS	ILLUMINA	1.601	false	
NUMB	NM_001005743	6741921	3	2	Homo sapiens	hg19	chr14	73833635	73822440	TGTAAAGGGCACAGCCAAGATTCAGA	6	AAAAATTAAAATGAACAAATTACGGCAAAG	1	MINUS	ILLUMINA	1.624	false	
OTX2	NM_021728	6820973	4	3	Homo sapiens	hg19	chr14	57270936	57269033	GAAAATCAACTTGCCCGAGTCGA	2	AAGAGCTAAGTGCCGCCAACAACA	1	MINUS	ILLUMINA	1.394	false	
PRKACA	NM_207518	6642799	7	6	Homo sapiens	hg19	chr19	14208429	14208252	ACCCCTGAGTACCTGGCCCCTGAGATTAT	2	TGGTGGGCCCTGGGGGTTCTTAT	4	MINUS	ILLUMINA	1.364	false	
PRKACB	NM_001242860	6835800	9	10	Homo sapiens	hg19	chr1	84663473	84668393	CAGAGTATTTGGCTCCAGAAATAATTCTC	1	TACAATAAGGCAGTGGATTGGTGGG	1	PLUS	ILLUMINA	1.77	false	
PTCH1	NM_001083607	6651382	2	1	Homo sapiens	hg19	chr9	98268719	98248113	GAGACCAACGTGGAGGAGCTGT	10	CGTGAATTAAATTATACTCGCCAGAAG	1	MINUS	ILLUMINA	1.435	false	
PTCH2	NM_001166292	6727647	3	2	Homo sapiens	hg19	chr1	45297858	45297689	ACTGCCAGTAAAGTCCAAGTATCACTC	1	TCCTGGGATTTGAACAAAATCTGCTAC	1	MINUS	ILLUMINA	1.997	false	
PTCHD1	NM_173495	6810817	1	2	Homo sapiens	hg19	chrX	23398340	23410684	CTTCCTGGGAGTCCCTTTCGTCAT	4	ATTATATGGGACTTTTGAAATGTTATCCTC	1	PLUS	ILLUMINA	1.462	false	
PTCHD2	NM_020780	6753021	18	19	Homo sapiens	hg19	chr1	11595147	11595562	CCTGCTCCTGCTGCCCGTGCTCCTCA	1	CATCGTGTGCCTGGTGGTGACCATCAT	1	PLUS	ILLUMINA	1.572	false	
PTCHD3	NM_001034842	6694153	1	0	Homo sapiens	hg19	chr10	27702129	27700831	ACCAACATTAAGAACATCTTGGCCTTG	2	TAGTCCACTTTACATCGCTTTCCAGAC	5	MINUS	ILLUMINA	1.997	false	
RAB23	NM_183227	6618339	6	5	Homo sapiens	hg19	chr6	57058674	57055357	TCCAGAACTAACGCATTCAAGTAGTAAC	1	CTGGTGGAAGTCACTCCGGTCAGAATT	1	MINUS	ILLUMINA	1.922	false	
RUNX2	NM_001024630	6741175	2	3	Homo sapiens	hg19	chr6	45390667	45399626	CAACAAGACCCTGCCCGTGGCCTTCAA	2	TAGCCCTCGGAGAGGTACCAGAT	2	PLUS	ILLUMINA	1.439	false	
SFRP1	NM_003012	6762932	1	0	Homo sapiens	hg19	chr8	41166169	41161014	GCCGCCCAATGCCACCGAAGCCTCCAA	1	CTGTGACAACGAGTTGAAATCTGAG	1	MINUS	ILLUMINA	1.577	false	
SHH	NM_000193	6799895	2	1	Homo sapiens	hg19	chr7	155599018	155596394	GGCACATATCCACTGCTCGGTGAAA	1	TCGGTGGCGGCCAAATCGGGAG	1	MINUS	ILLUMINA	1.256	false	
SMO	NM_005631	6697025	5	6	Homo sapiens	hg19	chr7	128846398	128848628	CTCATCGTGGGAGGCTACTTCCTCAT	1	TCATGACTCTGTTCTCCATCAAGAGC	1	PLUS	ILLUMINA	1.894	false	
STK3	NM_001256312	6702156	9	8	Homo sapiens	hg19	chr8	99608292	99591980	GAGCAGAGAGCTACTGCAACACAACTT	1	CAAGAATGCCAAACCTGTATCAATATT	1	MINUS	ILLUMINA	1.936	false	
STK36	NM_015690	6837823	11	12	Homo sapiens	hg19	chr2	219553572	219554609	CAGTCAGGAGAGCAACAGCCTCCA	3	CAATCTTGGTATGGGACCTTCTTACAGG	1	PLUS	ILLUMINA	1.679	false	
SUFU	NM_016169	6693347	8	9	Homo sapiens	hg19	chr10	104375132	104377075	CCGGAGCCCTCATTCCTCTCTGCCTAA	1	AGGCTCCTGCATGGACGGCACTTTA	1	PLUS	ILLUMINA	1.682	false	
TP53	NM_001126114	6709182	7	6	Homo sapiens	hg19	chr17	7577524	7577127	ACCATCATCACACTGGAAGACTCCA	2	AATCTACTGGGACGGAACAGCTTTG	1	MINUS	ILLUMINA	1.771	false	
VEGFA	NM_003376	6801905	2	3	Homo sapiens	hg19	chr6	43745368	43746240	GTGTGCCCACTGAGGAGTCCAACATCA	1	CAAGGCCAGCACATAGGAGAGAT	5	PLUS	ILLUMINA	1.53	false	
WIF1	NM_007191	6670299	1	0	Homo sapiens	hg19	chr12	65514854	65514301	ATCGATGCTCACCAGGCAAGAGTA	2	AAGATATCCTGATTGTTTCAGAGGGGA	1	MINUS	ILLUMINA	1.762	false	
WNT1	NM_005430	6638607	1	2	Homo sapiens	hg19	chr12	49373472	49374237	GGCCCCACCTCTTCGGCAAGATCGTCAA	1	CGAGAAACGGCGTTTATCTTCGCTAT	1	PLUS	ILLUMINA	1.755	false	
WNT10A	NM_025216	6855951	2	3	Homo sapiens	hg19	chr2	219755057	219757533	GGCTTCACAACAACCGAGTTGGGA	1	ATGCGGCGGAAGTGCAAGTGCCA	4	PLUS	ILLUMINA	1.287	false	
WNT10B	NM_003394	6604871	4	3	Homo sapiens	hg19	chr12	49361757	49360298	GAATCCACAACAACAGGGTGGGG	6	ACCTGAAGCGGAAATGCAAGTGTCAT	1	MINUS	ILLUMINA	1.563	false	
WNT11	NM_004626	6639399	4	3	Homo sapiens	hg19	chr11	75902636	75898247	AAGGTGGGCTCCCACGGGACACAAGA	1	ATCCAACGGAAGCGACAGCTGC	3	MINUS	ILLUMINA	1.253	false	
WNT16	NM_057168	6671818	2	3	Homo sapiens	hg19	chr7	120971984	120978962	CAATGAACCTACATAACAATGAAGCTGG	1	GTCGCCAAGTTGATGTCAGTAGACT	1	PLUS	ILLUMINA	1.852	false	
WNT2B	NM_004185	6623664	4	5	Homo sapiens	hg19	chr1	113059977	113062945	CCAGATTACTGTGTCTTGGACAAGGCT	1	GTGTCTGCAGCAAGACATCAAAA	4	PLUS	ILLUMINA	1.619	false	
WNT3	NM_030753	6632408	3	2	Homo sapiens	hg19	chr17	44847174	44846138	AGCACAACAACGAGGCGGGCCG	7	TCCTGGACCACATGCACCTCAAAT	2	MINUS	ILLUMINA	1.152	false	
WNT3A	NM_033131	6700943	2	3	Homo sapiens	hg19	chr1	228238597	228246714	GCCACAACAACGAGGCTGGGCG	8	CATCGCCAGCCACATGCACCTCAAGT	1	PLUS	ILLUMINA	1.252	false	
WNT4	NM_030761	6825168	1	0	Homo sapiens	hg19	chr1	22469365	22456310	CTTCTCAGCCGCCGCGAGCAACT	1	CAAGCTGTCGTCGGTGGGGAGCATCT	1	MINUS	ILLUMINA	1.329	false	
WNT5A	NM_003392	6834452	2	1	Homo sapiens	hg19	chr3	55514845	55513555	CGCCCAGGTTGTAATTGAAGCCAATT	1	TGAATAACCCTGTTCAGATGTCAGAAG	1	MINUS	ILLUMINA	1.962	false	
WNT5B	NM_032642	6696709	2	3	Homo sapiens	hg19	chr12	1742037	1748874	CAACGCATCTGTCTTTGGGAGAGTCAT	1	CAGCCGAGAGACCGCCTTCACCCA	1	PLUS	ILLUMINA	1.593	false	
WNT6	NM_006522	6668333	1	2	Homo sapiens	hg19	chr2	219735939	219736249	AGCAAGGCCTTTGGACGCATCCTGCAA	1	TGTTCGCCATCACTGCGGCCGG	1	PLUS	ILLUMINA	1.258	false	
WNT7B	NM_058238	6745651	3	2	Homo sapiens	hg19	chr22	46327010	46319182	ATGAACCTGCATAACAATGAGGCCG	6	AGGACCGGATGCAGCTGGAGTGCAAGT	1	MINUS	ILLUMINA	1.713	false	
WNT8A	NM_058244	6692087	3	4	Homo sapiens	hg19	chr5	137423586	137424638	CTGTGGCTGTGATGGGTCAAACAAT	1	AGGCCATGGCTGGATCTGGGGA	25	PLUS	ILLUMINA	1.313	false	
WNT8B	NM_003393	6629105	3	4	Homo sapiens	hg19	chr10	102240850	102241706	GGCTGTGATGACTCCCGCAACG	7	GCTGGCTGTGGGGAGGCTGCAGTGACAAT	2	PLUS	ILLUMINA	1.104	false	
WNT9A	NM_003395	6702393	2	1	Homo sapiens	hg19	chr1	228112989	228112075	CTACCGGGCCAGCCTGCTCAAG	8	TTCAAGGAGACTGCCTTCCTCTATG	1	MINUS	ILLUMINA	1.288	false	
ZIC1	NM_003412	6849799	1	2	Homo sapiens	hg19	chr3	147130438	147131165	GCATCCCAGTTCGCTGCGCAAACACAT	1	CACGAATCCTCCTCGCAGGGCT	4	PLUS	ILLUMINA	1.309	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
BCL2	NM_000633	6665875	FIVE_PRIME	false	1	0	MINUS	AGTATTGTTAATATCAGTCTACTTCCTCTGTGATGTTGTATTTTTTAAGTACAGCATGATCCTCTGTCAA
BMP2	NM_001200	6770547	THREE_PRIME	false	1	2	PLUS	GGTTGTTTTCCCACTCGTTTCTGGTAGTTCTTCCAAAGATTCTTCATGGTGGAAGCTGCGCACAGTGTTGGCTCGGCT
BMP4	NM_130851	6717860	THREE_PRIME	false	3	2	MINUS	AAAAGCAGAGTTTTCACTGGTCCCTGGGATGTTCTCCAGATGTTCTTCGTGGTGGAAGCTCCTCACGGTGTTGGCCCGGCT
BMP5	NM_021073	6778350	THREE_PRIME	false	6	5	MINUS	GCACAACAAGGCTTTGGTACGTGGTCAGGAAACATCAGATGAACCAGAGTCTGAACTATAGCGTGGTTGGTGGCA
BMP6	NM_001718	6833559	FIVE_PRIME	false	0	1	PLUS	TTTGTGGTGTCGCTGACGAGGGGAGAACTCCTTGTCGTACTCCACCAGGTTCACAAAGCTCATGACCATGTCCGC
BMP7	NM_001719	6634273	FIVE_PRIME	false	1	0	MINUS	GGTGGAAGAATTCCTTGTCATGTTCCACGAGGTTGACGAAGCTCATGACCATGTCG
BMP8B	NM_001720	6845976	THREE_PRIME	false	6	5	MINUS	TTGGGGACTGCGTCTGGCATCATCAGGTGCACCAGGGACTGCAGGATGGCGTGGTTGGTGGCATTCATG
BOC	NM_033254	6709878	THREE_PRIME	false	18	19	PLUS	TCTTCAACTGGCACAAGGCCCAAGCAGCATGGGGGCCCTGAGTGAAATGGAGGGTCCCACACTGCTTCCAGG
BTRC	NM_033637	6714787	THREE_PRIME	false	13	14	PLUS	CTGGTATTGGCAGATACGTTAAATACCGCAACTTTAATGGGTCCTGGGCAAGTATGAGGTCAGTGTATGGTTAT
CDON	NM_016952	6673362	THREE_PRIME	false	18	17	MINUS	GAAAGTGCTGTTGGTTTTGGTGAAACACCTATTGTTGTTTCGACAATTTCGGCAGTTAACACA
CSNK1A1	NM_001025105	6653540	THREE_PRIME	false	10	9	MINUS	TCTGCTCTGCTTCTTCTGTTCCTCAATTCATGCTTAGAAACCTTTCATGTTACTCTTGGTTTTGTCAGTTTGCTTG
CSNK1E	NM_152221	6740751	FIVE_PRIME	false	2	1	MINUS	CTTGATGGCGACTTCCTCACCAGAGGCGATGTTGGCACCCAGGTAGATATCTCCGAAGGACCCGCTCCC
CTNNB1	NM_001098210	6833702	THREE_PRIME	false	13	14	PLUS	TGGCCATATCCACCAGAGTGAAAAGAACGATAGCTAGGATCATCCTGGCGATATCCAAGGGGTTCTCCCTGGGCACC
DHH	NM_021044	6674108	FIVE_PRIME	false	1	0	MINUS	AAAGCGTTCACCCGCTCCTTACAACGCTCGGTCATCAGGCGGTCGGCTCCAC
DISP1	NM_032890	6652808	CENTER	false	3	4	PLUS	TTGGCAACTTGAAAGGTCTGGATGGTCTTATGTTGGCTATGTGCTGTTGCACAGGC
DISP2	NM_033510	6623257	THREE_PRIME	false	6	7	PLUS	CGAAGCTGGTATGGGAGCGGATCTGGTCCTGTTCCATGCGACACATGGAA
ERBB4	NM_005235	6613541	NA	false	4	3	MINUS	AGTACAGGACTTATGGCAACGTCCACATCCTGAACTACCATTTGTTGACACAAGAGTCAAG
FAT4	NM_024582	6598269	THREE_PRIME	false	15	16	PLUS	TTCTCCACCATACCACATAGAAGCAATGCAGCCATCAAAACCTGCTGTTTGGGCATCTCGATGTGCTTGAT
FBXW11	NM_033644	6625020	CENTER	false	6	5	MINUS	CTTTCAAACATTCCAGGCTGGTTTTATCCCATATCTTAATAGAATTATCTCGTAGGCCACTGATA
FGF9	NM_002010	6790719	THREE_PRIME	false	1	2	PLUS	GTTCTCTGAATACACACTCTTGGGTTAGTTTTTCTGATCCATACAGCTCCCCCTTCTCATTCATCCC
FGFR3	NM_001163213	6698989	THREE_PRIME	false	16	17	PLUS	AGTACTGCTCGAAAGGCGCCGACAGGTCCAGGTACTCGTCGGTGGACGTCACGGTAAGGACACGGT
FKBP8	NM_012181	6644398	CENTER	false	5	4	MINUS	TTCAACTGCAGGAGCTGTGCCTCCTCCTCGAACGTCATGTCCACTTTGGCGCTGGAGGTGATAGCCTTGATGGCGA
FOXE1	NM_004473	6598612	FIVE_PRIME	false	0	0	PLUS	ACACGAACCGATCTATCCCACCGGGATAAGCGGCAGCATGGCGAGCATGGTAGGCGCCTGCACTGGCCCCTCCGA
FRMD6	NM_001042481	6686039	THREE_PRIME	false	13	14	PLUS	AAGCTGTGTCGATCAGTGGAGGTCTTTGGTTTCCGACATATAGTCTGTGGAAGAGAATCAGTACTCTGGCCACGA
GLI1	NM_005269	6633250	CENTER	false	8	9	PLUS	TATAGCGTTTGGTGCAGCCAGGGAGCTTACATACATACGGCTTCTCATTGGAATGGGTCCGATTCTGGTGCTTGGCTC
GLI2	NM_005270	6709455	FIVE_PRIME	false	1	2	PLUS	AGATGTCAGAGATGACAGGGCTGCCGCTGAGGGCAGGGGGCCCGTGCACACCGTGGACAGAATGAGGCTC
GLI3	NM_000168	6785534	CENTER	false	4	3	MINUS	AGGTCCGGATACGTAGGGCTACTAGATAAGGCGGAAGTCATATGCAATGGAGGAATCGGAGATGGATCGTAA
GSK3B	NM_002093	6801970	NA	false	5	4	MINUS	ATTGGGTTCTCCTCGGACCAGCTGCTTTGCACTTCCAAAGTCACAGAGTTTTAATACAGCAGTATCAG
HHAT	NM_018194	6786133	CENTER	false	8	9	PLUS	ATGCTGGGACCCGCCCACTGGAATGTACACATACCTGATTAAGAAATTATGCAGTCCAACATC
HHIP	NM_022475	6860759	FIVE_PRIME	false	1	2	PLUS	GCAAAACTCATCCGCAGTTGTTTGAAGGAAACCTGGAATATGGCCTCGGCAAGTGTAAAAGAA
IFT52	NM_016004	6695277	CENTER	false	7	8	PLUS	TTTAGGTGGATGTCTCCTGTCGTGAGCCACTGGAAAACAACATCCATGATTTTGCTGTTTTCTTCTTTGTCCAAATATT
KCTD11	NM_001002914	6773911	FIVE_PRIME	false	0	0	PLUS	ACCTCGGGGAGTTCCACGGGGCGGGGGGCCCACTCCAGATGAAAATGTGGGCTCCCCTCTGCCCT
LATS1	NM_004690	6758732	THREE_PRIME	false	7	6	MINUS	CTTGTGGTGGAATGTGAAGAGATGTTTGCCAGTTGATAACCTTCATTTGTGTTTCTAATGGTGTTTGTGCCAAGA
LATS2	NM_014572	6819358	CENTER	false	2	1	MINUS	TCTGCTTGAGAGCTCGGCCAGCCATCTCCTGGTCGCATCCTGCGTTCACCAGTT
LRP2	NM_004525	6840096	FIVE_PRIME	false	2	1	MINUS	ACTTGAAATAGCCCTGCTGGCAGGTCACAACAGCGCAGCCAATTTCATCCGCGTCATCTGAACA
MAPK1	NM_002745	6638935	CENTER	false	5	4	MINUS	GTCTTCTTGTGATGGGGATCCAAGAATACCCAAAATGTGGTTCAGCTGGTCAAGATAATGCTTC
MTSS1	NM_014751	6725119	NA	false	3	2	MINUS	TGAGAGCAGATCCAATCTCCCTGGTCCCACCACGTGTGTTGGTGGCCATGTCAGCCA
NF2	NM_181832	6761335	THREE_PRIME	false	13	14	PLUS	GATGCTTGCTCTTTTCCATGTATTCCACTTTTTCTTTCTCTATCTCCATGGAAAGCCGCTTCAT
NPC1	NM_000271	6627112	CENTER	false	9	8	MINUS	AAGGGTCATGGAGCAAACTTGTATCATTCAGAGAGGCAGGAGCCCGTACGCAGTACAGAAAGTGCGTGTGGTAAT
NUMB	NM_001005743	6741921	CENTER	false	3	2	MINUS	CTTTGCCGTAATTTGTTCATTTTAATTTTTACAGCCTGGCTCTGAATCTTGGCTGTGCCCTTTACA
OTX2	NM_021728	6820973	FIVE_PRIME	false	4	3	MINUS	TGTTGTTGGCGGCACTTAGCTCTTCGATTCTTAAACCATACCTGCACCCTCGACTCGGGCAAGTTGATTTTC
PRKACA	NM_207518	6642799	NA	false	7	6	MINUS	ATAAGAACCCCCAGGGCCCACCAGTCCACGGCCTTGTTGTAGCCTTTGCTCAGGATAATCTCAGGGGCCAGGTACTCAGGGGT
PRKACB	NM_001242860	6835800	THREE_PRIME	false	9	10	PLUS	CCCACCAATCCACTGCCTTATTGTAGCCCTTGCTGAGAATTATTTCTGGAGCCAAATACTCTG
PTCH1	NM_001083607	6651382	FIVE_PRIME	false	2	1	MINUS	CTTCTGGCGAGTATAATTTAATTCACGACTTACTCGTCCTCCAACTTCCACCCACAGCTCCTCCACGTTGGTCTC
PTCH2	NM_001166292	6727647	CENTER	false	3	2	MINUS	GTAGCAGATTTTGTTCAAATCCCAGGACTTCCCATAGAGTGATACTTGGACTTTACTGGCAGT
PTCHD1	NM_173495	6810817	THREE_PRIME	false	1	2	PLUS	GAGGATAACATTTCAAAAGTCCCATATAATCCATGACCTAGCATGACGAAAGGGACTCCCAGGAAG
PTCHD2	NM_020780	6753021	THREE_PRIME	false	18	19	PLUS	ATGATGGTCACCACCAGGCACACGATGCCCAAGATGCTGAGGAGCACGGGCAGCAGGAGCAGG
PTCHD3	NM_001034842	6694153	FIVE_PRIME	false	1	0	MINUS	GTCTGGAAAGCGATGTAAAGTGGACTACCTCAATTTTTTTCAAGGCCAAGATGTTCTTAATGTTGGT
RAB23	NM_183227	6618339	THREE_PRIME	false	6	5	MINUS	AATTCTGACCGGAGTGACTTCCACCAGATGTATTAAAGACACCAATCTTGTTACTACTTGAATGCGTTAGTTCTGGA
RUNX2	NM_001024630	6741175	FIVE_PRIME	false	2	3	PLUS	ATCTGGTACCTCTCCGAGGGCTACCACCTTGAAGGCCACGGGCAGGGTCTTGTTG
SFRP1	NM_003012	6762932	FIVE_PRIME	false	1	0	MINUS	CTCAGATTTCAACTCGTTGTCACAGGGAGGACACACCGTTGTGCCTTGGGGCTTGGAGGCTTCGGTGGCATTGGGCGGC
SHH	NM_000193	6799895	THREE_PRIME	false	2	1	MINUS	CTCCCGATTTGGCCGCCACCGAGTTCTCTGCTTTCACCGAGCAGTGGATATGTGCC
SMO	NM_005631	6697025	CENTER	false	5	6	PLUS	GCTCTTGATGGAGAACAGAGTCATGACTCCTCGGATGAGGAAGTAGCCTCCCACGATGAG
STK3	NM_001256312	6702156	CENTER	false	9	8	MINUS	AATATTGATACAGGTTTGGCATTCTTGATAAAAGGATGCTGTAAAAGTTGTGTTGCAGTAGCTCTCTGCTC
STK36	NM_015690	6837823	CENTER	false	11	12	PLUS	CCTGTAAGAAGGTCCCATACCAAGATTGCTGCTGGAGGCTGTTGCTCTCCTGACTG
SUFU	NM_016169	6693347	THREE_PRIME	false	8	9	PLUS	TAAAGTGCCGTCCATGCAGGAGCCTGCCCCTTAGGCAGAGAGGAATGAGGGCTCCGG
TP53	NM_001126114	6709182	THREE_PRIME	false	7	6	MINUS	CAAAGCTGTTCCGTCCCAGTAGATTACCACTGGAGTCTTCCAGTGTGATGATGGT
VEGFA	NM_003376	6801905	THREE_PRIME	false	2	3	PLUS	ATCTCTCCTATGTGCTGGCCTTGGTGAGGTTTGATCCGCATAATCTGCATGGTGATGTTGGACTCCTCAGTGGGCACAC
WIF1	NM_007191	6670299	FIVE_PRIME	false	1	0	MINUS	TCCCCTCTGAAACAATCAGGATATCTTCTTCAAATCCTATGAGTACTCTTGCCTGGTGAGCATCGAT
WNT1	NM_005430	6638607	THREE_PRIME	false	1	2	PLUS	ATAGCGAAGATAAACGCCGTTTCTCGACAGCCTCGGTTGACGATCTTGCCGAAGAGGTGGGGCC
WNT10A	NM_025216	6855951	THREE_PRIME	false	2	3	PLUS	TGGCACTTGCACTTCCGCCGCATGTTCTCCATCACTGCCTGCCTCCCAACTCGGTTGTTGTGAAGCC
WNT10B	NM_003394	6604871	THREE_PRIME	false	4	3	MINUS	ATGACACTTGCATTTCCGCTTCAGGTTTTCAGTTACCACCTGGCGCCCCACCCTGTTGTTGTGGATTC
WNT11	NM_004626	6639399	THREE_PRIME	false	4	3	MINUS	GCAGCTGTCGCTTCCGTTGGATGTCTTGTTGCACTGCCTGTCTTGTGTCCCGTGGGAGCCCACCTT
WNT16	NM_057168	6671818	THREE_PRIME	false	2	3	PLUS	AGTCTACTGACATCAACTTGGCGACAGCCTGCCTTCCAGCTTCATTGTTATGTAGGTTCATTG
WNT2B	NM_004185	6623664	THREE_PRIME	false	4	5	PLUS	TTTTGATGTCTTGCTGCAGACACGGCCTGCAGTGCCTAGGGAACCTGCAGCCTTGTCCAAGACACAGTAATCTGG
WNT3	NM_030753	6632408	NA	false	3	2	MINUS	ATTTGAGGTGCATGTGGTCCAGGATAGTCGTGCGGCCCGCCTCGTTGTTGTGCT
WNT3A	NM_033131	6700943	THREE_PRIME	false	2	3	PLUS	ACTTGAGGTGCATGTGGCTGGCGATGGCCTGGCGCCCAGCCTCGTTGTTGTGGC
WNT4	NM_030761	6825168	FIVE_PRIME	false	1	0	MINUS	AGATGCTCCCCACCGACGACAGCTTGGCCAGGTACAGCCAGTTGCTCGCGGCGGCTGAGAAG
WNT5A	NM_003392	6834452	FIVE_PRIME	false	2	1	MINUS	CTTCTGACATCTGAACAGGGTTATTCATACCTAGCGACCACCAAGAATTGGCTTCAATTACAACCTGGGCG
WNT5B	NM_032642	6696709	CENTER	false	2	3	PLUS	TGGGTGAAGGCGGTCTCTCGGCTGCCTATCTGCATGACTCTCCCAAAGACAGATGCGTTG
WNT6	NM_006522	6668333	FIVE_PRIME	false	1	2	PLUS	CCGGCCGCAGTGATGGCGAACACGAAGGCCGTCTCCCGAATGTCCTGTTGCAGGATGCGTCCAAAGGCCTTGCT
WNT7B	NM_058238	6745651	THREE_PRIME	false	3	2	MINUS	ACTTGCACTCCAGCTGCATCCGGTCCTCTAGAACCTTCCTGCCGGCCTCATTGTTATGCAGGTTCAT
WNT8A	NM_058244	6692087	CENTER	false	3	4	PLUS	TCCCCAGATCCAGCCATGGCCTCCTGTTTTTCCATTGTTTGACCCATCACAGCCACAG
WNT8B	NM_003393	6629105	THREE_PRIME	false	3	4	PLUS	ATTGTCACTGCAGCCTCCCCACAGCCAGCCTTGTCCCCCCAGTTGCCCGTTGCGGGAGTCATCACAGCC
WNT9A	NM_003395	6702393	CENTER	false	2	1	MINUS	CATAGAGGAAGGCAGTCTCCTTGAAGCCTCGCTTGAGCAGGCTGGCCCGGTAG
ZIC1	NM_003412	6849799	THREE_PRIME	false	1	2	PLUS	AGCCCTGCGAGGAGGATTCGTGGACCTTCATGTGTTTGCGCAGCGAACTGGGATGC
